NSC-Logo-Graphics

 Live chat by LivePerson
 

Pulsing Mode with PowerPak

Novaseal’s proprietary pulsing feature is activated when the mode Selector switch is pointing to the letter P.

In pulsing mode, the heat sealer will automatically cycle through SEAL1, COOL1, SEAL2, COOL2 timers.  COOL1 is the time between Seals 1 and 2.  COOL1 time is what assures that the seal does not distort the material or distort the printed colors.  COOL1 time also assures that the plastic material surface does not burn. 

An example setting for timers could be:

SEAL1

3 seconds

Typical range:  1 to 5 seconds

COOL1

3 seconds

Typical range:  2 to 4 seconds

SEAL2

3 seconds

Typical range:  1 to 5 seconds

COOL2

6 seconds

Typical range:  5 to 12 seconds

All Rights Reserved, (c) 1994-2013

Novaseal Corporation      Tel: 561-470-3267