Sample Parameters

These Puls2™ parameters are for reference purposes only & not a performance specification. Actual parameters used will vary based on materials used and experience.

In addition to reduced cycle times, Puls2TM can also have a significant affect on increased heating element life and zone tape life.

  

Blackout Material

PLS

0.4

PWD

0.15

MLPS

12

COOL

5.0

Total heat seal cycle time:  10.6 seconds (compared to 15 sec prior to Puls2TM upgrade.)

  

Vinyl Material

PLS

0.4

PWD

0.15

MLPS

11

COOL

4.0

Total heat seal cycle time:  10.0 seconds (compared to 12 sec prior to Puls2TM upgrade.)

  

"4000" 3% Material

PLS

0.4

PWD

0.15

MLPS

18

COOL

7.0

Total heat seal cycle time:  17.0 seconds (compared to 20.5 sec prior to Puls2TM upgrade.)

  

"TempE" Material

PLS

0.4

PWD

0.15

MLPS

24

COOL

8.0

Total heat seal cycle time:  21.0 seconds (compared to 30.0 sec prior to Puls2TM upgrade.)